Skip to main content

Kickoff: the carried prior where the ownship's legs outlast the 2-hour window

· 3 min read

Spec 031 found that a 1-hour window with a carried prior is no substitute for a longer window or a joint solve. But with ownship legs of 1–2 h, a 2-hour window always contains a turn. The owner's case is a leg longer than the standing 2-hour window, so that the window itself is blind. Spec: specs/032-long-legs/.

Where we are​

  • Standing: ctl on 2-hour windows, with spec 028's ctl-prior (the previous window's state and uncertainty as a prior, with a guard) for tended contacts.
  • Spec 029: on blind 1-hour windows the prior beat the window alone (about 1.7 to 2.4).
  • Spec 031:
    • A joint solve over the same past bearings beat the 1-hour prior (0.774 [0.632, 0.954]).
    • Not tested: legs longer than the 2-hour window.

Where this task moves to​

  • Engagements: the ownship holds each leg for 2–4 h, with the same realism. The range drifts out, so about half of bearings are lost at long range.
  • Systems on turn-free 2-hour windows:
    • 2-hour ctl;
    • 2-hour ctl-prior;
    • a joint solve: ctl on the window and the one before it, 3.5 h, past bearings only.
  • Rules:
    • E1 = ctl ÷ ctl-prior; E2 = joint ÷ ctl-prior. Each ends "ctl-prior better", "worse" or "not separated".
    • Harm: E1 on one-turn windows has its upper limit below 1.
  • Plan:
    1. tuning on spent seed 366;
    2. the decision record;
    3. validation on seed 367;
    4. test on seed 368, scored once;
    5. the panel, then the write-up.
  • Risks:
    • Lost contact thins the turn-free windows. Held windows are far-range windows.
    • The joint solve's cost on 3.5 h is unknown.

How progress will be shown​

  • E1 and E2 with intervals, and per-window ratios.
  • Errors by system, by range band and by detected share.
  • Guard rate, and coverage and NEES of the 2-hour hand-overs.
  • Compute per engagement-hour.

Update, 2026-11-21: the owner adopted 2-hour ctl-prior​

After the write-up, the owner adopted 2-hour ctl-prior as the standing chained time-late system for the tended contact on long engagements.

  • Settings: spec 028's carry2 at its registered settings, on 2-hour windows overlapping 30 minutes, up to 12 hours.
  • Control: ctl stays as the control.
  • Alternative: the joint solve is the equal alternative where the bearings are kept.

The adoption carries the panel's limits:

  • It is one simulator, contact 1.
  • The gain on blind windows is a far-range one.
  • Windows are placed past true manoeuvres.
  • The carried covariance is not calibrated, so it is not shown as an uncertainty.
  • Spec 028's hand-over defect is kept.

Closing the long-engagement track with a synthesis is not yet chosen.