Long engagements: the carried prior where the ownship's legs outlast the window
The owner's hypothesis: knowledge of the previous track can usefully constrain the solution for the next leg. Spec 031 found that with ownship legs of 1–2 h, the standing 2-hour window always contains a turn, so the prior had nothing to rescue. This study makes the ownship hold each leg for 2–4 h, so some standing 2-hour windows are blind.
The result: on blind 2-hour windows, ctl ÷ ctl-prior is 1.54 [1.16, 2.03], and the
registered rule reads "ctl-prior better". Against a joint solve over the same past bearings it
is 1.11 [0.84, 1.45], not separated. The prior does no harm on windows with one turn; it helps
there too, at 1.26.
Spec: specs/032-long-legs/. Record: experiments/20261120-legs/.
The design
- Engagements: spec 024's realism, with ownship legs of 2–4 h, contact 1, and 6- and 12-hour engagements.
- Windows: the standing configuration, 2-hour windows overlapping 30 min.
- Systems on blind (turn-free) windows:
ctl, the window solved alone;ctl-prior, which carries the previous window's state and covariance as a prior, with spec 028's guard;- a joint solve:
ctlon the window and the one before it, 3.5 h of past bearings.
- Estimands:
- E1 =
ctl÷ctl-prior; E2 = joint ÷ctl-prior. - Harm is read on one-turn windows.
- Each is a geometric mean of per-window median range error, with a bootstrap over engagements.
- E1 =
- Registration: before seeds 367 and 368 existed. The test was raised to 50 + 50 engagements
on tuning's yield (
experiments/20261120-legs-decision/).
What happened
Test: seed 368, 100 engagements, scored once. Soundness passed.
| reading | range | median | ctl-prior better | twice as good / twice as bad |
|---|---|---|---|---|
E1 ctl ÷ ctl-prior | 1.537 [1.156, 2.029] | 1.25 | 59% | 38% / 18% |
E2 joint ÷ ctl-prior | 1.113 [0.840, 1.445] | 1.24 | 61% | 24% / 19% |
| harm (one-turn windows) | 1.259 [1.056, 1.500] | 1.21 | 60% | 31% / 16% |
-
Median range error on decided blind windows:
system median error ctl16.7% joint 12.8% ctl-prior10.4% reference told the true history 3.3% -
The prior does the work, not the carried start:
ctl-carry÷ctl-prioris 1.52. -
The forecasts came true: E1 "better" (probability 0.45), E2 "not separated" (0.5), no harm (0.95).
What the panel narrowed
Three reviewers each approved with findings (experiments/20261120-legs/review.md). Every decided
number was reproduced independently.
- Half the blind windows are outside the claim.
- Holding a 2–4 h leg opens the range, often beyond detection. 80 of 165 blind windows were lost to contact (median 72 km) and are unscored.
- The claim covers the 85 where contact held: median 37 km, about half the bearings detected.
- It is a far-range effect.
- E1 is about 2.2 beyond 35 km and about 1.0 under; at 15–25 km it is 0.82.
- Range and contact loss move together here and cannot be separated.
- E1 is "more data beats no data". E2 is the fair comparison, and the compact hand-over is not shown to lose to keeping the bearings, nor to beat them.
- The prior comes from a window that saw a turn in 83 of 85 cases. Chains of blind windows are untested.
- Seeds move.
- E1 was 1.32, 0.87 and 1.54 across the three seeds; pooled, it is 1.37 [1.05, 1.80].
- The joint solve against
ctlflipped between seeds; pooled, it is not separated.
- The carried uncertainty is not calibrated. It is too wide in the core and too narrow in the tail, and covers 0.79 across a turn.
- Limits:
- windows are placed past true manoeuvres;
- spec 028's hand-over defect is kept;
- one simulator, contact 1.
What it means for the owner's question
A qualified yes.
- Where the ownship holds course through the whole window and the target is far, the previous track constrains the next window far better than the window alone: about twice as well beyond 35 km.
- It does about as well as re-solving the previous bearings, and needs only four numbers and a covariance.
At ordinary ranges the benefit is not shown. Where contact is lost, nothing in this design answers well.
Next (the owner's choice)
- Recommended default:
- Adopt 2-hour
ctl-priorwith its guard as the standing chained system for the tended contact, up to 12 h, within the limits above. - Keep the joint solve as the equal alternative where the bearings are kept.
- Close the long-engagement track with one synthesis of specs 023 to 032.
- Adopt 2-hour
- Alternatives:
- an E2 study at ordinary ranges (15–25 km, range kept while holding course);
- repair the hand-over and the process-noise shape, then check coverage across a turn;
- predict through lost-contact windows and score both systems there.